MB05 - MB11 - MB25 - MB33Công ty TNHH Thương Mại Và Dịch Vụ Tăng Minh Phát (TMP Vietnam) là nhà phân phối của hãng Nireco tại thị trường Việt Nam, chuyên về ứng dụng trong ngành sản xuất màng nilong , in nhãn màng nilong, sản xuất bao bì, … các thiết bị như bộ điều khiển lực căng Nireco, hệ thống kiểm tra chất lượng in màng Nireco, bộ đo vị trí Nireco, cảm biến chỉnh biên Nireco, cảm biến đo lực căng Nireco,...
Overview
The MB Tension Sensor was designed to be used with a tension controller or tension meter.
It supports a wide range of products, with any tension range. The MB Tension Sensor has long been a strong seller, since sales were launched 20 years ago.
Feature
- Proven Track Record and Reliability
Without bearings or similar mechanical contacts, and employing a non-contact detection method using a differential transformer, the MB Tension Sensor is highly responsive with low hysteresis. The compact size also requires little space for installation. - Easy to Install
The MB 05, 11, and 25 can be installed at any angle. - Wide Selection of Sensors
①Full range available, from low tension (100 N full scale) to high tension (10,000 N full scale)
②All sensors have intrinsically safe construction. - Overload Resistant
The durable construction provides resistance to momentary overloads.
Specifications
Model | MB05B | MB05A | MB11B | MB11A | MB25B | MB25A | MB33B | MB33A | MB41 |
---|---|---|---|---|---|---|---|---|---|
Rated tension (N) | (50)100 | 200 | (50)100 | 200 | 500 | 1000 | (2000) 3000 | 5000 | 10000 |
Roll displacement (μm/N) | 2.38 | 1.19 | 2.63 | 1.30 | 0.44 | 0.22 | 0.071 | 0.045 | 0.023 |
Allowable roll weight (kg) | 10 | 20 | 10 | 20 | 50 | 100 | 300 | 350 | 700 |
Allowable overload (N) | Ten times rated load | ||||||||
Unit weight (kg) | 1.5 | 0.8 | 3.4 | 16.1 | 24 | ||||
Tension resultant direction | Forward or reverse possible | Forward only (reverse impossible) | |||||||
Mounting angle | Any desired angle | ||||||||
Supply voltage | DC +6V | ||||||||
Ambient temperature | -10 to +60℃ | ||||||||
Applicable bearings | - | ||||||||
Note 1. Figures for rated tension and allowable roll weight are for double-sided detection. For single detection the above figures should be halved. 2. A 5m cable with connectors for connection to an amplifier is supplied. 3. MB05, MB11 and MB25 can be wall mounted with a bracket. If the unit is equipped with a bracket, "-W" is added to the end of its model name. e.g. MB11B-W. 4. Sensors with inherently intrinsic safety construction are also available. "S" is added to the end of the corresponding model name. e.g. MB11BS. |